WPW10310240 Programming Instructions
After installing the new control board part number WPW10310240 the display will flash PE0000. This means the refrigerator is in programming mode and you will need to enter the program code from the model and serial number tag on the refrigerator. Please follow the instructions below to program the new control board. We have come across two different programming versions for this control board depending on the model refrigerator. Please make sure to look at both versions to see which one applies to your refrigerator. Also, on some model refrigerators the door(s) may need to be opened to program.
Programming Mode (Version 1):
NOTE: The Program Code is located on the Serial Plate on this unit after the word Code.
1. Press and hold the Door Alarm Keypad DoorAlarm.
2. Press and hold Freezer Temperature Down Keypad.
3. Release the Door Alarm Keypad DoorAlarm and wait 3 seconds.
4. The control will display PE to indicate the programming mode.
5. Entry is confirmed by pressing the Freezer Temperature Down Keypad once more.
6. The control will display the current Program CODE. This value should be validated with the Program CODE printed on the unit serial plate.
NOTE: If the Program CODE is correct, the Programming Mode is exited by pressing Door Alarm Keypad for 3 seconds.
7. Press the Refrigerator Temperature Up Keypad or Refrigerator Down Keypad to change the digit value with each key press.
8. The decimal point indicates the selected digit. Press the Freezer Temperature Up Keypad to select the next digit.
9. Once the desired Program CODE is entered, press and hold the Freezer Temperature Down Keypad until the Program CODE begins flashing indicating it has been saved.
NOTE: If you attempt to enter an invalid Program CODE the control will not save the new code, but will beep. (The unit will NOT run with a Program CODE of 0000). Once the Program CODE has been saved the Programming Mode is exited by pressing any key. If the new code is incorrect this process should be repeated. The Programming mode can be exited at any time by pressing Door Alarm key for 3 seconds or will exit if unattended for four minutes.
Programming Mode (Version 2):
NOTE: The Program Code is located on the Serial Plate on this unit after the word Code.
1. Press and hold the WATER Keypad.
2. Press and hold LL Keypad.
3. Release the WATER Keypad and wait 3 seconds.
4. The control will display PE to indicate the programming mode.
5. Entry is confirmed by pressing the LL Keypad once more.
6. The control will display the current Program CODE. This value should be validated with the Program
CODE printed on the unit serial plate.
NOTE: If the Program CODE is correct, the Programming Mode is exited by pressing water
Keypad for 3 seconds.
7. Press the UR Keypad or LR Keypad to change the digit value with each key press.
8. The decimal point indicates the selected digit. Press the UL Keypad to select the next digit.
9. Once the desired Program CODE is entered, press and hold the LL Keypad until the Program CODE
begins flashing indicating it has been saved.
NOTE: If you attempt to enter an invalid Program CODE the control will not save the new code, but will
beep. (The unit will NOT run with a Program CODE of 0000).Once the Program CODE has been saved
the Programming Mode is exited by pressing any key or by opening or closing the refrigerator door. If
the new code is incorrect this process should be repeated.
The Programming mode can be exited at any time by pressing WATER key for 3 seconds or will exit if
unattended for four minutes.
If you need to purchase a new control board please click the link below to purchase this part from our website:
High Voltage Control Board – Part # PD00003682 Mfg # WPW10310240
I followed directions, but when I enter proper code, unit still beeps. I noted others had similar problem. Is there a solution without entering 9999 codes?
Very happy with everything starting with calling response , part that I order, delivery also
Big Thank you
Highly recommended, these guys are the best
The programming mode 1 worked perfectly for me. Thank you. I read code 2020 from inside my fridge on the serial number plate, and and now my beer is getting cold again.
Thanks,
The new board is in and the programming code is set so I can use the control settings. How ever, I don’t hear the compressor or cooling fans operating. Any suggestions?
How long has it been? Some refrigerators have a 15 minute delay before it will kick on the compressor and start cooling.
Replaced the control board, entered the correct code, now my refrigerator runs, but will not shut off. Everything inside is freezing.
Trying to enter the code but when I press the up arrow on the left there is no decimal point showing.
Same problem, how did you fix
Hi
I replaced the control board but when trying to program the new control board the decimal point isn’t showing. Please help!
Replaced the control board per your instructions works wonderfully . The programming went great as well. Saved me a lot of money doing it myself. Thank. You
We have the same problem. No decimal point. Help?
Renee
Same problem. No decimal point showing! Did you figure it out?
Nevermind…I figured it out.
Katie – what was the solution? I’m having same problem – no decimal point.
We are having the same problem. No decimal point. Would love to know the solution.
The instructions fail to say that step 2 must be done within 3 seconds of step 1 for the decimal point to be displayed. Once we found another site that had that crucial information, we were able to program the correct code and get our refrigerator to work.
I have replaced both boards on my whirlpool ref. It will not go into program mode. When I let go of display buttons, the display goes blank.
Becky,
I am having the same exact problem. How did you get your problem fixed?
I have the control board but there’s no program code any where on the unit? What do I do now?
I do not have a code listed on my serial plate either. I have bought a refurbished board to replace the current one which works fine except for light on refrigerator side. I am hesitant to unplug and try to install refurbished one without a code, then I’m worse off than I am now.
How did you fix your problem without a code?.
Same Here! I have a 2015 Whirlpool Gold Series WRF736SDAM13. I Bought a replacement Control Board and went to write down the CODE off the serial plate in the fridge….And it was never printed there! Am I dead in the water without it? Can I replace this new control board without that Code? Will the Fridge recognize the new Board?
Any help is appreciated.
I have a whirlpool gold model GI5SVAXL01. I’ve tried version 1 and it does absolutely nothing. Still flashing PE0000. Can’t do version 2 because I don’t have LL button.
Did u find the issue of the00000 flashing?
Adam, did you find a fix?? I’m in the same boat as you – replaced the control board and for the life of me I can’t get it to program anything.
The LL is the freezer – button
The UL is the freezer + button
I am also having the problem with the decimal point not showing up. Does anyone know how to get it going?
Hi everyone,
I have a Maytag Trilogy Fridge Freezer. Model G32026PELB and the Control Board has given up. I have bought a replacement and need a Program Code but the label with it on has been scraped off the fridge. Does anyone know what the code is?
Thanks in advance,
Dan
I bought a new control board . But there is NO CODE on my refrigerator. Where can I find it ? Kenmore 106.56566400
I have same problem… No code on serial plate. No code on paperwork that came with the unit.
I am afraid to unplug unit to try to replace and be worse off than I am now .
Kathy, There was no code on mine either. Mine was mfg on 3/05, its on the plate. Maybe yours is also older and they didn’t need/use codes that’s why its not there.
OK, was thinking that I’ve had power failures due to storms and never had to reprogram anything so,
I just swapped a refurbished one in for mine on 4/25/2020 and so far everything seems to be working normally.
ice dispenses, water dispenses, frig light works, compressor runs, temp controls for freezer and frighted were the same as before I swapped. I would suggest you go for it.
David, what did you swap out for a refurbished one? I just replaced the control board but can’t program the fridge – it just keeps displaying PEOOOO.
My board was replaced and is flashing PE0000 but none of the directions make it stop flashing or the decimal show up. I tried door open and shut
I replaced the board and got to flashing PE 0000 on the programming sequence. But when I push the refer temp up or down all i get is “H2O” or “ICE”. I don’t get numbers or decimals. Am I doing something wrong?
I also can’t get into program mode and only see H20 ICE only
Same issue with mine last night. has anyone found a solution to this?
I also was having same problem of not seeing the decimal point showing up and experimented with various things. Eventually it worked by trial and error. If I remember correctly, I think what made it work was keeping the right door of the fridge open before resetting the control panel. I give credit to one of the commenters in the video (https://www.youtube.com/watch?v=bKwR05FCVWQ&t=161s) for pointing that out.
I’ve replaced the control board and was able to get into program mode but it will not accept the code. The code on my serial plate is 1411. Did anyone have this happen and what was your fix if so?
Did u fix it ? I have the samecode and isn’t working
hi, I’ve seen 3 comments with the same problem but, I currently have trouble with fixing my fridge, i got the circuit board in, but when I put in power PE0000 flashes, and when I press up or down on the fridge side it turns from PE0000 to PE H2O or PE ICE, there is no decimal, but nothing I do works
I have the exact same problem as vincent Ngo any solution?
Same problem
Method One worked like a charm! Thank you!!